Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
Ann Surg ; 2024 Mar 22.
Article in English | MEDLINE | ID: mdl-38516777

ABSTRACT

OBJECTIVE: The aim of the present study was to compare long-term post-resection oncological outcomes between A-IPMN and PDAC. SUMMARY BACKGROUND DATA: Knowledge of long term oncological outcomes (e.g recurrence and survival data) comparing between adenocarcinoma arising from intraductal papillary mucinous neoplasms (A-IPMN) and pancreatic ductal adenocarcinoma (PDAC) is scarce. METHODS: Patients undergoing pancreatic resection (2010-2020) for A-IPMN were identified retrospectively from 18 academic pancreatic centres and compared with PDAC patients from the same time-period. Propensity-score matching (PSM) was performed and survival and recurrence were compared between A-IPMN and PDAC. RESULTS: 459 A-IPMN patients (median age,70; M:F,250:209) were compared with 476 PDAC patients (median age,69; M:F,262:214). A-IPMN patients had lower T-stage, lymphovascular invasion (51.4%vs. 75.6%), perineural invasion (55.8%vs. 71.2%), lymph node positivity (47.3vs. 72.3%) and R1 resection (38.6%vs. 56.3%) compared to PDAC(P<0.001). The median survival and time-to-recurrence for A-IPMN versus PDAC were 39.0 versus19.5months (P<0.001) and 33.1 versus 14.8months (P<0.001), respectively (median follow-up,78 vs.73 months). Ten-year overall survival for A-IPMN was 34.6%(27/78) and PDAC was 9%(6/67). A-IPMN had higher rates of peritoneal (23.0 vs. 9.1%, P<0.001) and lung recurrence (27.8% vs. 15.6%, P<0.001) but lower rates of locoregional recurrence (39.7% vs. 57.8%; P<0.001). Matched analysis demonstrated inferior overall survival (P=0.005), inferior disease-free survival (P=0.003) and higher locoregional recurrence (P<0.001) in PDAC compared to A-IPMN but no significant difference in systemic recurrence rates (P=0.695). CONCLUSIONS: PDACs have inferior survival and higher recurrence rates compared to A-IPMN in matched cohorts. Locoregional recurrence is higher in PDAC but systemic recurrence rates are comparable and constituted by their own distinctive site-specific recurrence patterns.

2.
Ann Surg ; 2023 Oct 24.
Article in English | MEDLINE | ID: mdl-37873663

ABSTRACT

OBJECTIVE: This international multicentre cohort study aims to identify recurrence patterns and treatment of first and second recurrence in a large cohort of patients after pancreatic resection for adenocarcinoma arising from IPMN. SUMMARY BACKGROUND DATA: Recurrence patterns and treatment of recurrence post resection of adenocarcinoma arising from IPMN are poorly explored. METHOD: Patients undergoing pancreatic resection for adenocarcinoma from IPMN between January 2010 to December 2020 at 18 pancreatic centres were identified. Survival analysis was performed by the Kaplan-Meier log rank test and multivariable logistic regression by Cox-Proportional Hazards modelling. Endpoints were recurrence (time-to, location, and pattern of recurrence) and survival (overall survival and adjusted for treatment provided). RESULTS: Four hundred and fifty-nine patients were included (median, 70 y; IQR, 64-76; male, 54 percent) with a median follow-up of 26.3 months (IQR, 13.0-48.1 mo). Recurrence occurred in 209 patients (45.5 percent; median time to recurrence, 32.8 months, early recurrence [within 1 y], 23.2 percent). Eighty-three (18.1 percent) patients experienced a local regional recurrence and 164 (35.7 percent) patients experienced distant recurrence. Adjuvant chemotherapy was not associated with reduction in recurrence (HR 1.09;P=0.669) One hundred and twenty patients with recurrence received further treatment. The median survival with and without additional treatment was 27.0 and 14.6 months (P<0.001), with no significant difference between treatment modalities. There was no significant difference in survival between location of recurrence (P=0.401). CONCLUSION: Recurrence after pancreatic resection for adenocarcinoma arising from IPMN is frequent with a quarter of patients recurring within 12 months. Treatment of recurrence is associated with improved overall survival and should be considered.

3.
J Colloid Interface Sci ; 397: 177-84, 2013 May 01.
Article in English | MEDLINE | ID: mdl-23484766

ABSTRACT

Microplating that (i) does not necessitate complex or precise machinery to dispense small liquid volumes, (ii) enables fluorescent optical diagnosis, and (iii) permits simple analyte mixing mechanically is desirable. We advance here a novel approach that employs the formation of a liquid bridge held in place by capillary forces between glass rod tubes located parallel to each other. Experimental investigations made on liquid filling characteristics show conformance to theoretical notions. Analytical development showed the presence of regions of minimal uncertainty in the cross-sectional area of the liquid body arising from variations in the contact angle which permit consistent fluorescence measurements. Cyclical translation of the rods relative to each other, which cause rupture and reattachment of the liquid bridge, was found to engender good mixing. Strong linear trends were found in fluorescence signals relative to EGFP fluorophore concentration using standard and optical fiber (which offer targeted) excitation illumination. The open nature of liquid handling in the approach reported here and the positive results obtained portend the ability for development as integrated lab-on-a-chip devices.


Subject(s)
Glass , Microfluidic Analytical Techniques , Models, Theoretical , Fluorescence , Green Fluorescent Proteins/chemistry
4.
Anal Biochem ; 430(1): 53-5, 2012 Nov 01.
Article in English | MEDLINE | ID: mdl-22864233

ABSTRACT

Two important challenges in microplate instrumentation are to achieve full well sample coverage and complete mixing. An effective approach of using superhydrophobic rods to accomplish these challenges is reported here. Experiments conducted showed that analytes above 50µl could be made to completely cover the bottom of 96-well standard and transparency microplates. Complete mixing was accomplished by moving the rod parallel to the well bottom while contacting the liquid. The approach is simple and controlled, and it minimizes the problems of spillage and cross-contamination. It works with analytes with varied volumes and of different viscosities present in each well of the microplate.


Subject(s)
Hydrophobic and Hydrophilic Interactions , Microtechnology/instrumentation , Wettability
5.
J Colloid Interface Sci ; 365(1): 314-9, 2012 Jan 01.
Article in English | MEDLINE | ID: mdl-21986403

ABSTRACT

Pressure differentials are routinely used to actuate flow in capillaries. We advance here an alternative means of flow generation that capitalizes on the extension of a liquid bridge achieved by the drawing of a rod through the action of surface tension. This meets the exigencies of creating controllable flow using simpler and more compact means. We found the ability to generate controllable flow to be strongly affected by the liquid bridge sustaining features, and that the use of rod diameters larger than the capillary was more conducive. The extensional flow resulting from the rupture of the liquid bridge was also found to have a strong circulation component which facilitated mixing. The approach here is highly amenable for use in capillary well microplates which have significant advantages over standard microplates. The features of this approach offer usage possibilities in biochemical applications in the field, such as in the leukocyte cell adhesion and hemagglutination tests of blood samples.


Subject(s)
Microfluidic Analytical Techniques , Polymethyl Methacrylate , Animals , Cell Adhesion , Hemagglutination , Humans , Leukocytes/cytology , Leukocytes/metabolism , Surface Tension
6.
J Fluoresc ; 21(5): 1835-9, 2011 Sep.
Article in English | MEDLINE | ID: mdl-21559858

ABSTRACT

The preconcentration of analytes is important in biochemical analysis as it offers the ability to detect for trace species, and increase signal-to-noise ratios when using optical sensing on fluorophores. A strong advantage of the evaporation technique lies in its ability to operate without the need of any energy source; albeit major challenges exist on how to increase the surface area exposure to air for heightened evaporation, ensure no further increases once specified analyte concentrations have been achieved, and not needing any intervening membranes. We demonstrate here that the droplet creation and retraction approach in capillary based microplates offers such abilities whilst at the same time facilitating mixing.


Subject(s)
Desiccation , Fluorescence , Microtechnology/instrumentation , Microtechnology/methods , Proteins/analysis , Proteins/isolation & purification , Time Factors
7.
Phys Rev E Stat Nonlin Soft Matter Phys ; 83(2 Pt 2): 026304, 2011 Feb.
Article in English | MEDLINE | ID: mdl-21405903

ABSTRACT

In a fully formed rivulet, the flow profile across the total cross section is downward, as would be intuitively expected. However, prior to this stage being reached, a strong backflow capable of carrying particles up to 125 mm up the incline back to the source is shown to occur. Two phases are described prior to a fully formed rivulet being established. First, a forming rivulet, in which a bulbous drop head slides down a slope with a flow occurring in the wetted trail behind it. In this stage, a linear increase in backflow height is observed over time. Subsequently, a transient rivulet occurs, with the transition happening once the end of the inclined solid surface is reached. The backflow decreases through this phase in a stepwise manner, coinciding with fluid dripping off the surface. The findings here strongly challenge common assumptions made regarding cleaning, whereby fluid will transport particulate matter downhill, and has significant implications on irrigation applied to remove bacterial biofilms in clinical medicine.

8.
Anal Biochem ; 410(1): 152-4, 2011 Mar 01.
Article in English | MEDLINE | ID: mdl-21078285

ABSTRACT

Sample/reagent mixing is important in microplate instrumentation and the approach of mixing prior to dispensation into the wells can be problematic when assays involve a mixture of different proportions of reagents. We demonstrate here with capillaries, a simple and highly effective method that uses air actuation and liquid surface tension to create pendant drops in which the inherent inner circulatory flow within accomplishes mixing. The approach portends the capability to be incorporated into microplates in order to provide a useful feature for assay investigations.


Subject(s)
Microtechnology/methods , Air , Motion , Pressure , Surface Properties
SELECTION OF CITATIONS
SEARCH DETAIL
...